CGNYT - IODINE, 13380

  • MSDS: CGNYT
  • Manufacturer: SIGMA CHEMICAL CO
  • Product Name: IODINE, 13380
  • National Stock Number: 6550-00N082782
Product Identification

Product ID:IODINE, 13380
MSDS Date:11/01/1995
FSC:6550
NIIN:00N082782
MSDS Number: CGNYT

Responsible Party
SIGMA CHEMICAL CO
ST LOUIS, MO 63178
US

Emergency Phone: 800-325-3010; 314-771-5750

Info Phone: 800-325-3010; 314-771-5750

Cage: 21076

Contractor
SIGMA CHEMICAL COMPANY
14508 ST LOUIS, MO 63178 US

Telephone: 314-771-5765

Cage: 21076

Ingredients

IODINE

CAS: 7553-56-2

RTECS: NN1575000

OSHA PEL 0.1 PPM, C

ACGIH TLV: 0.1 PPM, C

Hazards

LD50 LC50 Mixture:LD50:(ORAL,RAT) 14 GM/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MAY BE FATAL IF INHALED,
SWALLOWED/ABSORBED THRU SKIN. MATL IS EXTREMELY DESTRUCT TO TISS OF
MUC MEMBS & UPPER RESP TRACT, EYES & SKIN. INHAL MAY BE FATAL AS
RSLT OF SPASM, INFLAMM & EDEMA OF LA RYNX & BRONCHI, CHEM PNEUM &
PULM EDEMA. SYMPS OF EXPOS MAY INCL BURNING SENSATION, COUGH,
WHEEZING, (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:LARYNGITIS, SHORTNESS OF BREATH, HDCH,
NAUS & VOMIT. EXPOS CAN CAUSE:STOM PAINS, VOMIT, DIARR. DMG TO
EYES. DERM. MAY CAUSE ALLERGIC RXN. TARGET ORG(S):THYROID. TARGET
ORG DATA:GI (HYPERMOTIL ITY, DIARR; OTHER CHANGES); ENDOCRINE (EVID
OF THYROID HYPERFUNC); EFTS ON NEWBORN (VIABILITY INDEX; GROWTH
STATISTICS).
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:IMMED FLUSH W/COPIOUS AMTS OF WATER FOR AT LST 15 MINS.
ASSURE ADEQ FLUSHING BY SEPARATING EYELIDS W/FINGERS. SKIN:IMMED
FLUSH W/COPIOUS AMTS OF WATER FOR AT LST 15 MINS WHILE REMOVING
CONTAM CLT HG & SHOES. DISCARD CONTAM CLTHG & SHOES. INHAL:IF NOT
BRTHG GIVE ARTF RESP. IF BRTHG IS DFCLT, GIVE OXYG. INGEST:WASH OUT
MOUTH W/WATER PROVIDED PERSON IS CONSCIOUS. CALL MD.

Fire Fighting

Extinguishing Media:DRY CHEMICAL POWDER.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:EMITS TOXIC FUMES UNDER FIRE CONDITIONS.

Accidental Release

Spill Release Procedures:EVACUATE AREA. WEAR NIOSH APPROVED SCBA,
RUBBER BOOTS & HEAVY RUBBER GLOVES. COVER W/DRY LIME OR SODA ASH,
PICK UP, KEEP IN CLOSED CONTAINER & HOLD FOR WASTE DISPOSAL.
VENTILATE AREA & WASH SPILL SITE AFTER MATERIAL PICKUP IS
COMPLETE.
Neutralizing Agent:DRY LIME OR SODA ASH.

Handling

Handling and Storage Precautions:DO NOT BREATHE VAP. AVOID CONT W/EYES,
SKIN & CLTHG. AVOID PRLNG/RPTD EXPOS. CORROSIVE. HIGHLY TOXIC. SEV
LACHRYMATOR. HARMFUL VAPOR. SENSITIZER.
Other Precautions:KEEP TIGHTLY CLSD. STORE IN COOL, DRY PLACE. TOX BY
INHAL, IN CONT W/SKIN & IF SWALLOWED. CAUSES BURNS. MAY CAUSE
SENSIT BY INHAL & SKIN CONT. IN CASE OF ACCIDENT/IF YOU FEEL
UNWELL, SEEK MED ADVICE I MMED (SHOW LABEL WHERE POSSIBLE).

Exposure Controls

Respiratory Protection:WEAR APPROPRIATE NIOSH APPROVED RESPIRATOR.
Ventilation:USE ONLY IN A CHEMICAL FUME HOOD.
Protective Gloves:CHEMICAL-RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . WEAR SUITABLE PROTECTIVE CLOTHING.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
MATLS TO AVOID:A VIOLENT REACTION OCCURS BETWEEN IODINE & ACETALDEHYDE.
EYE PROT:& FULL LENGTH FACESHIELD .

Chemical Properties

Spec Gravity:4.93
Appearance and Odor:SOLID.

Stability

Stability Indicator/Materials to Avoid:YES
MAGNESIUM, ZINC, AMMONIA, ALUMINUM, CORRODES STEEL. MIXING IODINE,
ANTIMONY & AMMONIA RESULTED IN AN EXPLOSION. (SUPDAT)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NATURE OF DECOMPOSITION PRODUCTS NOT
KNOWN.

Disposal

Waste Disposal Methods:MATERIAL IN ELEMENTAL STATE SHOULD BE RECOVERED
FOR REUSE OR RECYLCING. OBSERVE ALL FEDERAL, STATE & LOCAL
ENVIRONMENTAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.